[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Flowchart of approve and expert process::
indexing and abstracting::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 6, Issue 2 (summer 2015) ::
j.health 2015, 6(2): 226-235 Back to browse issues page
Heterotrophic Bacteria in Drinking Water Distribution System in Ardabil, Iran
M Alighadri , T Sadeghi * , P BagheriArdebilian , E Iranpour , SH Khodaverdi , A Alipanah
Ardabil University of Medical Sciences
Abstract:   (10058 Views)

Background & Objectives: The heterotrophic plate count (HPC) bacteria and total coliforms are often used as the indicators of disinfection process performance. The aim of this study was to determine HPC indicator in drinking water distribution system in Ardebil city, Iran in 2012. Methods: In this descriptive-analytical study, 42 water samples were taken randomly from Ardebil drinking water distribution system and their HPC, free chlorine residual, turbidity, pH, and temperature were measured. While the pour-plate technique was used for the HPC test and the R2A culture media were used. Data analysis was descriptive statistical and regression test. Results: In 71.4% of the samples heterotrophic bacteria were present. In 9.6% of samples the HPC was higher than 500 CFU/ml. The mean of HPC indicator in water samples was 140.02 CFU/ml (SD=227.22) and the mean of free chlorine residual concentration was 0.33mg/l (SD=0.32). In 21.4% of samples the free chlorine residual concentration was less than 0.2mg/l and in 19% of samples was zero. The range of turbidity in samples was within 0.05-3NTU. There was a significant correlation between the HPC and turbidity (R=0.67), the HPC and pH (R=0.261), the HPC and free chlorine residual (R=-0.347), the HPC and temperature (R=-0.231). Conclusion: Monitoring of HPC in drinking water distribution system in Ardebil city at periodically in order to identification of contaminated areas and free chlorine residual concentration supply the range of 0.2-0.8 mg/l is necessary as an important variable and effective in the control of drinking water bacteriological quality.

Keywords: Drinking Water, Heterotrophic Bacteria, HPC, Ardabil.
Full-Text [PDF 211 kb]   (6248 Downloads)    
Type of Study: Research | Subject: Special
Received: 2015/05/17 | Accepted: 2015/05/17 | Published: 2015/05/17
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Alighadri M, Sadeghi T, BagheriArdebilian P, Iranpour E, Khodaverdi S, Alipanah A. Heterotrophic Bacteria in Drinking Water Distribution System in Ardabil, Iran. j.health 2015; 6 (2) :226-235
URL: http://healthjournal.arums.ac.ir/article-1-593-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 2 (summer 2015) Back to browse issues page
مجله سلامت و بهداشت Journal of Health
Persian site map - English site map - Created in 0.14 seconds with 37 queries by YEKTAWEB 4623