[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Flowchart of approve and expert process::
indexing and abstracting::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 1, Issue 1 (summer 2010) ::
j.health 2010, 1(1): 14-23 Back to browse issues page
Evaluation of Corrosion and Precipitation Potential in Ardebil Drinking Water Distribution System by Using Langelier & Ryznar Indexes
S.A Mokhtari * , M Aalighadri , S Hazrati , H Sadeghi , N Gharari , L Ghorbani
Abstract:   (12176 Views)
Background and Objectives: Corrosion and sedimentation potential is one of the main factors in water quality control issues. Water tendency towards each of them, can be play very effective role in the transmission and distribution of drinking water in terms of economic and health aspects. The purpose of this study was evaluation of chemical quality, corrosive and sedimentation rate of drinking water in Ardabil water supply network and providing relevant solutions for probable problems. Methods: In a cross-sectional research conducted in autumn 2009, the city was divided into 12 blocks and water samples were taken in two instances (in the first half of October and the second half of December). Parameters of alkali, calcium hardness, electrical conductivity, temperature and pH were determined. Water samples were handled according to standard procedures, and corrosion and sedimentation potential were estimated using indicators Lanzhlyh (LSI) and Rayznr (RSI) . Results: The results of tests and calculations showed that the respective value for average of LSI index in the first and 2nd stage of water sampling was -0.23 and -0.46, and the average for RSI index in the first and 2nd stage of sampling was 7.98 and 8.24, respectively. Based on LSI index, drinking water in the water supply system has a tendency to corrosion in 9 and 12 stations in the first and second sampling campaigns, respectively with the other stations tending to have sedimentation. However, according to RSI index six stations had tendency to corrosion and others was balanced in the first samples. For the second samples, ten stations tend to have corrosive property and the others had conditions of relative equilibrium. Conclusion: Based on the results obtained, water in Ardabil drinking water supply have slight tendency to corrosion and water quality must be controlled for the relevant parameters e.g. pH, alkali, and hardness. Application of corrosion-resistant pipes and materials should be considered in drinking water networks.
Keywords: Corrosion, precipitation, Langelier & Ryznar Index, distribution system, Drinking Water, Ardabil
Full-Text [PDF 245 kb]   (3836 Downloads)    
Type of Study: Research | Subject: Special
Received: 2014/01/29 | Accepted: 2014/01/29 | Published: 2014/01/29
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mokhtari S, Aalighadri M, Hazrati S, Sadeghi H, Gharari N, Ghorbani L. Evaluation of Corrosion and Precipitation Potential in Ardebil Drinking Water Distribution System by Using Langelier & Ryznar Indexes. j.health 2010; 1 (1) :14-23
URL: http://healthjournal.arums.ac.ir/article-1-146-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 1, Issue 1 (summer 2010) Back to browse issues page
مجله سلامت و بهداشت Journal of Health
Persian site map - English site map - Created in 0.14 seconds with 37 queries by YEKTAWEB 4623